{"gross_floor_m2":140.844,"stories":3,"required_x_cm_per_m2":29.0,"actual_x_cm":3407.0,"required_x_cm":1648.476,"required_y_cm_per_m2":29.0,"actual_y_cm":3465.0,"required_y_cm":1648.476,"balance_x":1.0,"balance_y":0.4166666666666667,"pass":false,"messages":["Y方向壁量バランス不良: 端部1/4比 0.42 < 0.5","→ 修正案 (Y バランス): 端部 1/4 ゾーンに耐力壁を追加配置。現在の比 0.42 を 0.5 以上に。","N値推定: 端部柱最大 22.7 kN → 推奨金物: ホールダウン金物 HD-B25","計算仮定: 軽い屋根+2階建て係数29 cm/m² (令第46条 表3)、壁倍率は構造用合板2.5/筋交2.0/IFCWALLSTANDARDCASE1.5/汎用1.0 の簡易判定。N値は端部柱の保守側推定。層間変形角は弾性域で 1/(200×剛性比) で近似。実際の構造設計では各柱位置で個別計算 + 構造一級建築士の検証必須。","4号特例廃止 (2025-04-01) 区分: 新1号建築物 (構造計算書 + 適合性判定 必須) — 延べ床140.8㎡ / 3階建て"],"n_value_max_kn":22.7376,"joint_recommendation":"ホールダウン金物 HD-B25","story_drift_ratio":0.0024192486058115647,"story_drift_pass":true,"asd":{"vertical_load_kn_m2":3.4,"ci":0.2,"seismic_force_1f_kn":167.12136000000004,"wind_load_kn_m2":0.84,"eccentricity_x":0.047212620012117734,"eccentricity_y":0.3637059886714693,"stiffness_ratio":[1.0694778696243592,0.9036144578313253,0.9036144578313253],"column_max_stress_nmm2":12.632000000000001,"beam_max_stress_nmm2":7.232142857142857,"pass":false,"messages":["偏心率Y NG: 0.36 > 0.3","計算根拠: Z=1.0 Rt=1.0 C0=0.2 Ai_1F=1.0、固定+積載+仕上+雪=3.4kN/m²、風荷重=0.84kN/m² (V0=34m/s)、柱105×105、梁105×240。詳細は構造一級建築士確認必須。"],"basis":"建築基準法施行令第82条準拠 (簡易) / 建告1100号・1460号 / 4号特例廃止 2025-04-01 対応"}}